Harman p38 owners manual


















Table of Contents. For use in the u. For Your saFetY, Follow. Prevention bureau, etc. Previous Page. Next Page. For Your saFetY, Follow installation directions.

Page 4 Serial : This label is located on the back of the unit. Please copy the Serial Number for future reference. To free the stove from the skid you must remove the hold-down bolts in the rear of the pedestal base. Page 7: Installation 0 to Record the first reading. Connect flue pipe to stove and be sure all doors and windows in the home are closed.

If the second reading is more than. Page 8 I. Page 9: Outside Air The first piece of pipe must be fastened securely with at least 2 fasteners to the flue collar of the stove. Page Vent Configurations House demand may consume some air needed for the stove, especially during a power failure. It may be necessary to add additional ventilation to the space in which the pellet appliance is located.

Page 11 This vertical section will provide natural draft in the event of a power failure. If the stove is installed below grade be sure the vent termination is at least 18" above grade. The outlet 3 ft. If you discover that the chimney does not have a clay tile liner or has cracks or flaking of the tile liner you will need to install a stainless steel liner within the chimney. Page 13 The pipe or liner inside the chimney should be 4" diameter. In this method a cap should also be installed on the chimney to keep out rain.

Page 14 8 installing through the ceiling Through the ceiling vent, follow PL vent manufacturers recommendations when using wall and ceiling pass through. Minimum flue vent Status Light Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down.

Blinks to indicate errors listed below. Indicates power to the distribution blower. Page Operation In the Room Temperature Mode, with the optional room sensor attached, the stove constantly monitors the temperature in the room and adjusts the size of the fire and the heat output of the stove so that the room is kept at a constant temperature.

Page 17 If the stove is left to run out of fuel, you may get a 6 blink status light. Page 18 First, scrape the ashes off the front of the burn pot into the ash pan. Then, scrape the top surface of the burn pot downward into the base of the burn pot. When the stove is ignited these scrapings will be pushed out by the feeder and burned. Page Draft Test Procedure Be sure the intake flapper is opening and check for resistance in the outside air conduit if installed.

Page Maintenance "OFF" to allow the unit to shut down. Call the fire department, and be sure everyone is out of the residence.

Contact may cause skin burns. Side Shields. The clearance above grade must be a minimum of 18". A 12" clearance to a permanently closed window is recommended to prevent condensation on the window.

The vertical clearance to a ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center-line of the terminal must be a minimum of 18". The clearance to an unventilated soffit must be a minimum of 12".

The clearance to an outside corner is 11" from center of pipe. The clearance to an inside corner is 12". The clearance to service regulator vent outlet must be a minimum of 6 feet. The clearance to a non-mechanical air sup-. The clearance to a mechanical air supply inlet must be a minimum of 10 feet.

The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet. The appliance should be inspected before use and at least annually by a qualified service person.

More frequent cleaning will be required. It is imperative that control compartments, burners, and circulating air passageways of the stove be kept clean. Welcome to ManualMachine.

We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. Harman Stove Company. Failure to follow instructions may result in property damage, bodily injury, or even death. Unpacking Cut straps holding box together and remove box from skid.

Installing Rear Cover Panels The rear cover panels are removed from the stove to make it easier to get at the hold-down bolts. Firebrick Install the firebrick horizontally on the angle above the burnpot. Rear Cover Panels Flame Guide Install the cast iron flame guide on top of the burnpot and make sure it is fully seated against the auger opening. Assembling the door Door Glass. Install door on stove with hinge pins.

Turn the paw bolt "in" for approx. Align the set screw with the flat spot on the paw and tighten. Mobile Home Installation When installing this unit in a mobile home several requirements must be followed: 1. See page 8. Floor protection and clearances must be followed as shown. Unit must be grounded to the metal frame of the mobile home. In addition, the following must be observed: A. The clearance under a veranda, porch,deck or balcony must be a minimum of 12 inches.

You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need. View and download manuals available only for. Register and get 5 for free. Upload manuals that we do not have and get 1 for each file.